Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 100
Filtrar
1.
Arch Soc Esp Oftalmol (Engl Ed) ; 99(3): 98-108, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38216051

RESUMO

BACKGROUND AND OBJECTIVE: Recommendations on general glaucoma management and the use of early minimally invasive and microincisional surgeries are limited. This study aimed to establish consensus regarding glaucoma management, focusing on the XEN-45 gel stent implant. METHODS: A Delphi consensus-driven process was used. The scientific committee led the study, identified the expert panel, and participated in elaborating the questionnaire. Fifty-one panelists were invited to complete, on a nine-point Likert scale, an 89-item questionnaire covering three topic blocks. Two Delphi rounds were performed. Consensus was achieved if ≥66.6% of panelists reached agreement or disagreement. RESULTS: Panelists agreed on 84 items related to the patients' quality of life, the therapeutic algorithm and patient profile, and surgical and pre- and post-operative management. Panelists agreed on the suitability of XEN stent implants to treat glaucoma at different stages and for different patient profiles: young patients, elderly or with significant comorbidities, and with myopic glaucoma, patients who failed previous surgeries, and with previous poor post-operative experience. XEN surgery was considered a therapeutic step prior to classic filtering surgery and a possible first surgical option in elderly patients with comorbidities and uncontrolled intraocular pressure. XEN surgery allows the patient to return to routine daily activities faster than conventional filtering surgeries and to reduce and/or eliminate topical treatments. CONCLUSIONS: This Delphi-driven consensus resulted in a series of general recommendations for glaucoma management, including those related to patient quality of life, therapeutic algorithm, and patient profile, and specific ones regarding the use of XEN stent gel surgery.


Assuntos
Implantes para Drenagem de Glaucoma , Glaucoma , Humanos , Idoso , Técnica Delfos , Qualidade de Vida , Resultado do Tratamento , Glaucoma/cirurgia
2.
Arch Soc Esp Oftalmol (Engl Ed) ; 99(3): 91-97, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38043736

RESUMO

PURPOSE: To detect and characterise visual field (VF) defects using static Octopus perimetry in patients with primary congenital glaucoma (PCG) and to determine VF quality and time duration. MATERIAL AND METHODS: Eighty-eight eyes of 70 patients diagnosed with PCG were included. Assessments were performed using an Octopus 900 and each eye was assessed with the tendency-oriented perimetry (G-TOP) algorithm. Quantitative VF data were collected: quality data (false positive and negative response, and time duration) and results of mean deviation (MD) and square root of loss variance (sLV). Qualitative data were collected: the presence of diffuse and localized defects, the affected hemifield and grade of defects using the Aulhorn and Karmeyer classification. Correlations between perimetric results and clinical variables were analysed. RESULTS: Median age was 11 (8-17) years. 65.9% (58/88) of PCG eyes showed VF defects. Diffuse defects were observed in 10/58 eyes (16.94%) (mean MD = 23.92 [SD: 2.52]) dB) and localized defects in 48/58 eyes (82.75%). The most frequent defect was spot-like/stroke-like/incipient paracentral scotoma (n = 15), nasal step (n = 8), adding arcuate defect (n = 2), half ring-shaped (n = 13) and concentric defect with a central island (n = 9). And the most frequent affected visual hemifield was inferior hemifield. Mean test duration was 2 min 12 s (SD: 21.6 s). MD and sLV values were correlated with best corrected visual acuity (BCVA), cup to disc ratio and number of antiglaucoma surgeries (all P < .001). CONCLUSION: A high number of diffuse and localized defects were identified using Octopus perimetry in PCG patients. The most frequent defect was paracentral scotoma and inferior hemifield was the most affected.


Assuntos
Glaucoma , Testes de Campo Visual , Humanos , Criança , Testes de Campo Visual/métodos , Campos Visuais , Escotoma/diagnóstico , Escotoma/etiologia , Transtornos da Visão , Glaucoma/diagnóstico
3.
Arch. Soc. Esp. Oftalmol ; 98(12): 680-686, dic. 2023. ilus, tab, graf
Artigo em Espanhol | IBECS | ID: ibc-228143

RESUMO

Propósito Evaluar la capacidad diagnóstica de la densidad de vasos (DV) papilar y macular mediante angiografía por tomografía de coherencia óptica (OCTA) y el grosor de la capa de fibras nerviosas de la retina (CFNR) y complejo de células ganglionares (CCG) maculares mediante tomografía de coherencia óptica (OCT) en los pacientes con glaucoma seudoexfoliativo (GPX). Métodos Estudio transversal que incluyó GPX y controles sanos. Se realizó OCT y OCTA de la papila y el área macular con el OCT RS-3000 Advance (Nidek Co., Gamagori, Japón). Se registró la DV macular del plexo capilar superficial (SCP) y la DV papilar del plexo capilar peripapilar radial (RPCP). Se empleó el área bajo la curva característica operativa del receptor (AUROC) para determinar el poder discriminatorio de cada parámetro. Resultados El grosor de la CFNR y del CCG, así como la DV a nivel papilar y macular, fueron significativamente menores en los pacientes con GPX que en los controles sanos (todos, p<0,05). El mejor parámetro discriminante fue el grosor medio de la CFNR (AUROC: 0,928). El AUROC de la DV papilar fue mejor que el de la DV macular (AUROC: 0,897 y 0,780, respectivamente). AUROC de la DV papilar fue comparable a la del grosor de la CFNR (p<0,001).Conclusiones La capacidad diagnóstica de la DV papilar en el GPS parece comparable a la de los parámetros estructurales, espesor de la CFNR y CCG, obtenidos mediante OCT, por lo que la OCTA podría ser una herramienta valiosa en el GPX. (AU)


PurposeTo evaluate the diagnostic ability of the vessel density (VD) of the optic nerve head (ONH) and the macula on optical coherence tomography (OCT) angiography and the retinal nerve layer thickness (RNFL) thickness and the macular ganglion cell complex (GCC) thickness on OCT in patients with pseudoexfoliative glaucoma (PXG). Methods Cross-sectional study including PXG patients and healthy controls. Demographic and clinical data were noted for all participants. Optical coherence tomography (OCT) and OCT angiography (OCTA) images of the ONH and macular area were obtained with the RS-3000 Advance OCT (Nidek Co., Gamagori, Japan). The RNFL and GCC thickness of different sectors was provided by the software. Macular VD of the superficial capillary plexus (SCP) and ONH VD of the radial peripapillary capillary plexus (RPCP) were registered. Groups were compared and area under the receiver operating characteristic (AUROC) curves were used to determine the power of discrimination of each parameter. Results RNFL and GCC thickness and ONH and macular VD were significantly lower in PXG patients compared with healthy controls (all, P<.05). The best discrimination parameter was the average RNFL thickness (AUROC: 0.928). ONH VD AUROC was better than that of macular VD (AUROC: 0.897 and 0.780, respectively). ONH VD AUROC was comparable to RNFL thickness (P<.001).Conclusions The diagnostic ability of ONH vessel density in PXG appears comparable to that of the structural parameters, RNFL and GCC thickness, obtained with OCT, and may be a valuable tool in clinical practice. (AU)


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Tomografia de Coerência Óptica , Glaucoma/diagnóstico por imagem , Glaucoma/patologia , Sensibilidade e Especificidade , Estudos Transversais
4.
Arch Soc Esp Oftalmol (Engl Ed) ; 98(12): 680-686, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37788756

RESUMO

PURPOSE: To evaluate the diagnostic ability of the vessel density (VD) of the optic nerve head (ONH) and the macula on optical coherence tomography (OCT) angiography and the retinal nerve layer thickness (RNFL) thickness and the macular ganglion cell complex (GCC) thickness on OCT in patients with pseudoexfoliative glaucoma (PXG). METHODS: Cross-sectional study including PXG patients and healthy controls. Demographic and clinical data were noted for all participants. Optical coherence tomography (OCT) and OCT angiography (OCTA) images of the ONH and macular area were obtained with the RS-3000 Advance OCT (Nidek Co., Gamagori, Japan). The RNFL and GCC thickness of different sectors was provided by the software. Macular VD of the superficial capillary plexus (SCP) and ONH VD of the radial peripapillary capillary plexus (RPCP) were registered. Groups were compared and area under the receiver operating characteristic (AUROC) curves were used to determine the power of discrimination of each parameter. RESULTS: RNFL and GCC thickness and ONH and macular VD were significantly lower in PXG patients compared with healthy controls (all, p<0.05). The best discrimination parameter was the average RNFL thickness (AUROC: 0.928). ONH VD AUROC was better than that of macular VD (AUROC: 0.897 and 0.780, respectively). ONH VD AUROC was comparable to RNFL thickness (p<0.001). CONCLUSIONS: The diagnostic ability of ONH vessel density in PXG appears comparable to that of the structural parameters, RNFL and GCC thickness, obtained with OCT, and may be a valuable tool in clinical practice.


Assuntos
Glaucoma de Ângulo Aberto , Glaucoma , Disco Óptico , Humanos , Disco Óptico/diagnóstico por imagem , Disco Óptico/irrigação sanguínea , Tomografia de Coerência Óptica/métodos , Glaucoma de Ângulo Aberto/diagnóstico , Estudos Transversais , Pressão Intraocular , Vasos Retinianos/diagnóstico por imagem , Glaucoma/diagnóstico por imagem
5.
Arch. Soc. Esp. Oftalmol ; 98(6): 317-324, jun. 2023.
Artigo em Espanhol | IBECS | ID: ibc-221222

RESUMO

Objetivo Evaluar la reproducibilidad de la densidad vascular (DV) peripapilar, cabeza del nervio óptico (ONH-PP) y área macular mediante angiografía por tomografía de coherencia óptica de dominio espectral (SD OCT-A) en pacientes con glaucoma y en sujetos sanos. Métodos Estudio transversal que evaluó 63 ojos de 63 sujetos, incluyendo 33 pacientes con glaucoma y 30 sujetos sanos. El glaucoma se clasificó en leve, moderado o avanzado. Dos exploraciones consecutivas fueron adquiridas por Spectralis Module OCT-A (Heidelberg, Alemania) y proporcionaron imágenes del complejo vascular superficial (SVC), del plexo vascular de la capa de fibra nerviosa (NFLVP) y del plexo vascular superficial (SVP); del complejo vascular profundo (DVC), del plexo capilar intermedio (ICP) y del plexo capilar profundo (DCP). La DV (%) fue calculada mediante AngioTool. Se calcularon los coeficientes de correlación intraclase (ICC) y los coeficientes de variación (CV). Resultados Respecto a la DV de ONH-PP, el mejor ICC lo presentó el glaucoma avanzado (0,86-0,96) y moderado (0,83-0,97) en comparación con el glaucoma leve (0,64-0,86). Para la DV macular, los resultados de ICC para las capas retinianas superficiales fueron mejores para el glaucoma leve (0,94-0,96), seguido por el glaucoma moderado (0,88-0,93) y por el avanzado (0,85-0,91), y para las capas retinianas más profundas el ICC fue más alto para el glaucoma moderado (0,95-0,96), seguido por el glaucoma avanzado (0,80-0,86) y por el leve (0,74-0,91). Los CV oscilaron entre el 2,2% y el 10,94%. Entre los sujetos sanos, los ICC para las mediciones de DV ONH-PP (0,91-0,99) y para las mediciones de la DV macular (0,93-0,97) fueron excelentes en todas las capas, con CV del 1,65% al 10,33% (AU)


Objective To assess the reproducibility of peripapillary, optic nerve head (ONH-PP) and macular vessel density (VD) by spectral domain optical coherence tomography angiography (SD OCT-A) in glaucoma patients and healthy subjects. Methods Cross-sectional study assessing 63 eyes of 63 subjects, including 33 glaucoma patients and 30 healthy subjects. Glaucoma was classified in mild, moderate, or advanced. Two consecutive scans were acquired by spectralis module OCT-A (Heidelberg, Germany), and provided images of the superficial vascular complex (SVC), nerve fiber layer vascular plexus (NFLVP), superficial vascular plexus (SVP), deep vascular complex (DVC), intermediate capillary plexus (ICP) and deep capillary plexus (DCP). VD (%) was calculated by AngioTool. Intraclass correlation coefficients (ICCs) and coefficients of variation (CV) were calculated. Results Among ONH-PP VD, better ICC presented advanced (0.86-0.96) and moderate glaucoma (0.83-0.97) compared with mild glaucoma (0.64-0.86). For the macular VD reproducibility, ICC results for superficial retinal layers were better for mild glaucoma (0.94-0.96) followed by moderated (0.88-0.93) and advanced glaucoma (0.85-0.91), and for deeper retinal layers ICC was better for moderate glaucoma (0,95-0,96) followed by advanced (0.80-0.86) and mild glaucoma (0.74-0.91). CVs ranged from 2.2%% to 10.94%. Among healthy subjects, ICCs for the ONH-PP VD measurements (0.91-0.99) and for the macular VD measurements (0.93-0.97) were excellent in all layers, with CVs from 1.65% to 10.33%. Conclusions SD OCT-A used to quantify macular and ONH-PP VD showed excellent and good reproducibility in most layers of the retina, both in healthy subjects and in glaucoma patients regardless of the severity of the disease (AU)


Assuntos
Humanos , Glaucoma/diagnóstico por imagem , Nervo Óptico/diagnóstico por imagem , Macula Lutea/diagnóstico por imagem , Índice de Gravidade de Doença , Reprodutibilidade dos Testes , Tomografia de Coerência Óptica
6.
Arch Soc Esp Oftalmol (Engl Ed) ; 98(6): 317-324, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37023850

RESUMO

OBJECTIVE: To assess the reproducibility of peripapillary, optic nerve head (PP-ONH) and macular vessel density (VD) by Spectral Domain optical coherence tomography angiography (SD OCT-A) in glaucoma patients and healthy subjects. METHODS: Cross-sectional study assessing 63 eyes of 63 subjects, including 33 glaucoma patients and 30 healthy subjects. Glaucoma was classified in mild, moderate, or advanced. Two consecutive scans were acquired by Spectralis Module OCT-A (Heidelberg, Germany), and provided images of the superficial vascular complex (SVC), nerve fiber layer vascular plexus (NFLVP), superficial vascular plexus (SVP); deep vascular complex (DVC), intermediate capillary plexus (ICP) and deep capillary plexus (DCP). VD (%) was calculated by AngioTool. Intraclass correlation coefficients (ICCs) and coefficients of variation (CV) were calculated. RESULTS: Among PP-ONH VD, better ICC presented advanced (ICC 0.86-0.96) and moderate glaucoma (ICC 0.83-0.97) compared with mild glaucoma (0.64-0.86). For the macular VD reproducibility, ICC results for superficial retinal layers were better for mild glaucoma (0.94-0.96) followed by moderated (0.88-0.93) and advanced glaucoma (0.85-0.91), and for deeper retinal layers ICC was better for moderate glaucoma (0.95-0.96) followed by advanced (0.80-0.86) and mild glaucoma (0.74-0.91). CVs ranged from 2.2% to 10.94%. Among healthy subjects, ICCs for the PP-ONH VD measurements (0.91-0.99) and for the macular VD measurements (0.93-0.97) were excellent in all layers, with CVs from 1.65% to 10.33%. CONCLUSIONS: SD OCT-A used to quantify macular and PP-ONH VD showed excellent and good reproducibility in most layers of the retina, both in healthy subjects and in glaucoma patients regardless of the severity of the disease.


Assuntos
Glaucoma , Macula Lutea , Disco Óptico , Humanos , Disco Óptico/diagnóstico por imagem , Disco Óptico/irrigação sanguínea , Tomografia de Coerência Óptica/métodos , Estudos Transversais , Reprodutibilidade dos Testes , Angiofluoresceinografia/métodos , Vasos Retinianos/diagnóstico por imagem , Macula Lutea/diagnóstico por imagem , Macula Lutea/irrigação sanguínea , Glaucoma/diagnóstico por imagem
7.
J Fr Ophtalmol ; 46(8): 866-872, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37085371

RESUMO

OBJECTIVE: To evaluate the dependence of corneal hysteresis (CH) on non-central corneal thickness. METHODS: Cross-sectional study of 1561 eyes of 1561 healthy volunteers with IOP less than 21mmHg, open angles on gonioscopy and no prior eye surgeries or local or systemic diseases. Pentacam-Scheimpflug technology was employed to segment the cornea into 6 circular zones centered on the apex (zones 1-6) and to determine the mean corneal thickness of these areas. CH was measured with ORA. Univariate and multivariate linear regression models adjusted for age and sex were created to model the dependence of CH on corneal thickness in zones 1 to 6. RESULTS: In the univariate linear regression models, we found that CH was dependent on mean corneal thickness of zone 1 (B=0,004; R2=0.95%; P<0.001), zone 2 (B=0,004; R2=0.57%; P=0.002), zone 4 (B=0,005; R2=1.50%; P<0.001) and zone 6 (B=0,003; R2=0.92%; P<0.001). Similar results were obtained in the multivariate model (R2=3.46%; P<0.001). CONCLUSION: This study suggests a significant dependence of CH on non-central corneal thickness. The model of corneal thickness segmentation into circular zones centered on the corneal apex is able to explain 3.47% of the variation in CH measurements.


Assuntos
Glaucoma de Ângulo Aberto , Pressão Intraocular , Humanos , Tonometria Ocular , Voluntários Saudáveis , Estudos Transversais , Córnea/diagnóstico por imagem , Fenômenos Biomecânicos , Paquimetria Corneana
8.
J Fr Ophtalmol ; 46(3): 249-257, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36739259

RESUMO

PURPOSE: To evaluate the influence of corneal densitometry on portable applanation (Perkins) and rebound (iCare ic100 and PRO) tonometry. A secondary goal was to assess if there was a relationship between various corneal properties and the severity of primary open angle glaucoma (POAG). MATERIAL AND METHODS: Seventy-five eyes of 75 patients with primary open angle glaucoma were studied, divided by severity into 3 groups: 25 mild, 25 moderate and 25 advanced. Intraocular pressure (IOP) was measured 3 times in each participant with a Perkins applanation tonometer (PAT), a handheld version of the Goldman applanation tonometer (GAT), an iCare PRO and an iCare ic100. Mean values were then calculated. Corneal topography with the Pentacam HR (Oculus, Wetzlar, Germany) was also performed in all individuals. RESULTS: Mean age and sex were comparable in all groups, as were densitometry values (P>0.05). The mean visual field defect (MD) was 2.85 (±1.23) dB in the mild glaucoma group, 8.26 (±1.90) dB in the moderate group and 15.66 (±3.46) dB in the advanced group. Three multivariate regression analyses were performed. The first and second calculations assessed the effect of IOP obtained with iCare ic100 and PAT as dependent variables with age, sex, CCT and mean keratometry (Km) within the glaucoma subgroups and the global sample. The third analysis was carried out to assess the relationship between corneal densitometry as the dependant variable and the aforementioned corneal parameters among the glaucoma groups. In the first multivariate regression analysis, a statistically significant correlation was found between ic100 rebound tonometry and CCT in the POAG global sample (coef. 0.117; IC [-0.21-(-0.01)]; P=0.025). No statistically significant correlation was found in the subgroup analyses. In the second multivariate analysis, no significant correlation was found between PAT and CCT, Km, age or sex (P>0.05). In the third analysis, densitometry was correlated with age in all glaucoma subgroups (P<0.001) and with CCT in the moderate glaucoma subgroup (coef. -0.037; IC [-0.67-(-0.01)]; P=0.021). Tonometry appeared to be minimally influenced by corneal densitometry, with a mild positive linear correlation seen (R=0.03). IOP values were similar with 3 of the tonometers: PAT 16.07 (±3.18) mmHg, PRO 16.27 (±3.42) mmHg and ic100 15.17 (±4.28) mmHg. There was, however, a significant underestimation of IOP with ic100 (-0.89mmHg) compared to PAT (P=0.007). CONCLUSION: Corneal densitometry did not show significant differences between glaucoma severity groups. A positive correlation was seen with CCT and both corneal densitometry and age. No correlation was found with keratometry or severity of glaucoma. The influence of corneal densitometry on IOP measurements appears weak, with little clinical relevance identified.


Assuntos
Glaucoma de Ângulo Aberto , Glaucoma , Humanos , Glaucoma de Ângulo Aberto/diagnóstico , Estudos Prospectivos , Pressão Intraocular , Tonometria Ocular , Densitometria , Reprodutibilidade dos Testes
9.
Arch. Soc. Esp. Oftalmol ; 98(1): 2-10, ene. 2023. tab, ilus
Artigo em Espanhol | IBECS | ID: ibc-214329

RESUMO

Antecedentes y objetivo Evaluar el impacto económico en España derivado de la introducción del implante XEN®63 como alternativa quirúrgica en el manejo del glaucoma primario de ángulo abierto (GPAA) con o sin cataratas en pacientes refractarios. Materiales y métodos Se diseñó un análisis de impacto presupuestario para estimar los costes del tratamiento quirúrgico del GPAA desde la perspectiva del Sistema Nacional de Salud (SNS) español, en un horizonte temporal de1 año. Los comparadores considerados (trabeculectomía, esclerectomía profunda no perforante, válvula de Ahmed, iStent inject®, Preserflo® microshunt y XEN®45) se corresponden a los empleados en la práctica clínica pública española. Para el cálculo de la población diana, cuotas de mercado y uso de recursos en términos de visitas de seguimiento, procedimientos adicionales y complicaciones poscirugía, se emplearon datos de la literatura y se validaron con un panel de cuatro expertos. Los costes unitarios (€de2021) se obtuvieron de la base de datos ESALUD Resultados la inclusión de XEN®63 podría generar un ahorro de 2.569.737€ tras un año desde su introducción, derivado del ahorro en el coste del implante y del procedimiento (−423.120; −0,7%), de las visitas de seguimiento (−777.407€; −4,5%), de los procedimientos adicionales (−1.048.145€, −20,6%) y de las complicaciones poscirugía (−321.065€, −14,2%). Conclusiones La incorporación de XEN®63 en el arsenal quirúrgico para el tratamiento del GPAA refractario con y sin cataratas podría generar ahorros para el SNS (AU)


Background and objective To evaluate the economic impact in Spain derived from the introduction of the XEN®63 implant as a surgical alternative in the management of primary open angle glaucoma (POAG) with or without cataract in refractory patients. Materials and methods A budget impact analysis was designed to estimate the costs of surgical treatment of POAG from the perspective of the Spanish National Health System (NHS), over a time horizon of 1year. The comparators considered (trabeculectomy, deep non-perforating sclerectomy, Ahmed valve, iStent inject®, Preserflo® microshunt and XEN®45) correspond to those used in Spanish public clinical practice. For the calculation of the target population, market shares and resource use in terms of follow-up visits, additional procedures and post-surgery complications, data from the literature were used and validated with a panel of 4 experts. Unit costs (€2021) were obtained from the ESALUD database. Result The inclusion of XEN®63 could generate savings of €2,569,737 after one year since its introduction, derived from savings in the cost of the implant and procedure (−€423,120; −0.7%), follow-up visits (−€777,407; −4.5%), additional procedures (−1,048,145; −20.6%) and post-surgery complications (−€321,065; −14.2%). Conclusion The incorporation of XEN®63 in the surgical arsenal for the treatment of refractory POAG with and without cataracts could generate savings for the NHS (AU)


Assuntos
Humanos , Glaucoma de Ângulo Aberto/cirurgia , Custos de Cuidados de Saúde , Trabeculectomia/métodos , Glaucoma de Ângulo Aberto/economia , Extração de Catarata , Trabeculectomia/economia , Espanha
10.
Arch. Soc. Esp. Oftalmol ; 98(1): 40-57, ene. 2023. tab
Artigo em Espanhol | IBECS | ID: ibc-214332

RESUMO

Objetivo Ofrecer una serie de recomendaciones generales que sirvan de orientación en la evaluación y el manejo de la progresión glaucomatosa en la práctica clínica diaria a partir de la evidencia clínica de calidad existente. Métodos Tras la definición de los objetivos y del alcance de la guía se constituyó el grupo de trabajo que formuló las preguntas clínicas estructuradas siguiendo el formato PICO (Patient, Intervention, Comparison, Outcomes). Una vez evaluada toda la evidencia clínica existente con las herramientas AMSTAR2 (Assessment of Multiple systematic Rewiews) y Risk of bias de Cochrane de forma independiente por al menos dos revisores, se pasó a la formulación de recomendaciones siguiendo la metodología del Scottish Intercollegiate Guideline Network (SIGN). Resultados Se presentan recomendaciones con sus correspondientes niveles de evidencia que pueden ser de utilidad para la detección y el seguimiento de la progresión glaucomatosa con los distintos métodos disponibles y para el tratamiento de los pacientes. Conclusiones A pesar de que para muchas de las preguntas el nivel de evidencia científica disponible no es muy alto, esta guía de práctica clínica ofrece una revisión actualizada de los diferentes aspectos existentes relacionados con la evaluación y el manejo de la progresión glaucomatosa (AU)


Objective To provide general recommendations that serve as a guide for the evaluation and management of glaucomatous progression in daily clinical practice based on the existing quality of clinical evidence. Methods After defining the objectives and scope of the guide, the working group was formed and structured clinical questions were formulated following the PICO (Patient, Intervention, Comparison, Outcomes) format. Once all the existing clinical evidence had been independently evaluated with the AMSTAR2 (Assessment of Multiple Systematic Reviews) and Cochrane «Risk of bias» tools by at least two reviewers, recommendations were formulated following the Scottish Intercollegiate Guideline network (SIGN) methodology. Results Recommendations with their corresponding levels of evidence that may be useful in the interpretation and decision-making related to the different methods for the detection of glaucomatous progression are presented. Conclusions Despite the fact that for many of the questions the level of scientific evidence available is not very high, this clinical practice guideline offers an updated review of the different existing aspects related to the evaluation and management of glaucomatous progression (AU)


Assuntos
Humanos , Glaucoma/diagnóstico , Glaucoma/terapia , Progressão da Doença , Índice de Gravidade de Doença , Seguimentos , Fatores de Risco
11.
Arch Soc Esp Oftalmol (Engl Ed) ; 98(1): 40-57, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36089479

RESUMO

OBJECTIVE: To provide general recommendations that serve as a guide for the evaluation and management of glaucomatous progression in daily clinical practice based on the existing quality of clinical evidence. METHODS: After defining the objectives and scope of the guide, the working group was formed and structured clinical questions were formulated following the PICO (Patient, Intervention, Comparison, Outcomes) format. Once all the existing clinical evidence had been independently evaluated with the AMSTAR 2 (Assessment of Multiple Systematic Reviews) and Cochrane "Risk of bias" tools by at least two reviewers, recommendations were formulated following the Scottish Intercollegiate Guideline network (SIGN) methodology. RESULTS: Recommendations with their corresponding levels of evidence that may be useful in the interpretation and decision-making related to the different methods for the detection of glaucomatous progression are presented. CONCLUSIONS: Despite the fact that for many of the questions the level of scientific evidence available is not very high, this clinical practice guideline offers an updated review of the different existing aspects related to the evaluation and management of glaucomatous progression.


Assuntos
Glaucoma , Humanos , Glaucoma/diagnóstico , Glaucoma/terapia
12.
Arch Soc Esp Oftalmol (Engl Ed) ; 98(1): 2-10, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36427747

RESUMO

BACKGROUND AND OBJECTIVE: To evaluate the economic impact in Spain derived from the introduction of the XEN®63 implant as a surgical alternative in the management of primary open angle glaucoma (POAG) with or without cataract in refractory patients. MATERIALS AND METHODS: A budget impact analysis was designed to estimate the costs of surgical treatment of POAG from the perspective of the Spanish National Health System (NHS), over a time horizon of 1 year. The comparators considered (trabeculectomy, deep non-penetrating sclerectomy, Ahmed valve, iStent inject, Preserflo® microshunt and XEN®45) correspond to those used in Spanish public clinical practice. For the calculation of the target population, market shares and resource use in terms of follow-up visits, additional procedures and post-surgery complications, data from the literature were used and validated with a panel of 4 experts. Unit costs (€ 2021) were obtained from the ESALUD database. RESULTS: The inclusion of XEN®63 could generate savings of €2,569,737 after one year since its introduction, derived from savings in the cost of the implant and procedure (-€423,120; -0.7%), follow-up visits (-€777,407; -4.5%), additional procedures (-€1,048,145; -20.6%) and post-surgery complications (-€321,065; -14.2%). CONCLUSIONS: The incorporation of XEN63®in the surgical arsenal for the treatment of refractory POAG with and without cataracts could generate savings for the NHS.


Assuntos
Catarata , Glaucoma de Ângulo Aberto , Trabeculectomia , Humanos , Glaucoma de Ângulo Aberto/cirurgia , Espanha , Resultado do Tratamento , Catarata/complicações
13.
Arch Soc Esp Oftalmol (Engl Ed) ; 97(3): 161-164, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35248397

RESUMO

The objective of the present case is to describe a variation in the Preserflo Microshunt surgical technique, placing it in the posterior chamber to minimise the risk of endothelial cell loss in cases with a compromised endothelium. The patient was a 72-year-old pseudophakic woman, with granular dystrophy and a primary diagnosis of open-angle glaucoma presenting with a progressive visual field defect and an IOP of 26 mmHg with maximal medical therapy. The cornea had incipient stromal folds with an endothelial count of 700 cells/mm2. A Preserflo Microshunt was implanted in the posterior chamber to minimise the possibility of further damage to the corneal endothelium. Six months after surgery, the implant remains functional. The IOP is 9 mmHg without medications. As far as we know, this is the first Preserflo implanted in the posterior chamber described in the literature.


Assuntos
Glaucoma de Ângulo Aberto , Idoso , Córnea , Endotélio , Feminino , Glaucoma de Ângulo Aberto/tratamento farmacológico , Humanos , Pressão Intraocular
14.
Arch. Soc. Esp. Oftalmol ; 97(3): 161-164, mar. 2022. ilus
Artigo em Espanhol | IBECS | ID: ibc-208833

RESUMO

The objective of the present case is to describe a variation in the Preserflo Microshunt surgical technique, placing it in the posterior chamber to minimise the risk of endothelial cell loss in cases with a compromised endothelium.The patient was a 72-year-old pseudophakic woman, with granular dystrophy and a primary diagnosis of open-angle glaucoma presenting with a progressive visual field defect and an IOP of 26mmHg with maximal medical therapy. The cornea had incipient stromal folds with an endothelial count of 700 cells/mm2. A Preserflo Microshunt was implanted in the posterior chamber to minimise the possibility of further damage to the corneal endothelium. Six months after surgery, the implant remains functional. The IOP is 9mmHg without medications. As far as we know, this is the first Preserflo implanted in the posterior chamber described in the literature (AU)


El objetivo del presente caso es describir una variación en la técnica quirúrgica del Preserflo Microshunt colocándolo en la cámara posterior para minimizar el riesgo de pérdida de células endoteliales en casos con endotelio comprometido.Se trata de una mujer de 72 años pseudofáquica con una distrofia granular y diagnóstico primario de glaucoma de ángulo abierto que presentaba un defecto campimétrico que había progresado y una PIO de 26mmHg con tratamiento médico máximo. La córnea presentaba pliegues estromales incipientes con un recuento endotelial de 700 células/mm2. Se implantó un Preserflo Microshunt en la cámara posterior para minimizar la posibilidad de daño adicional al endotelio corneal. Seis meses después de la cirugía el implante permanece funcionante, con una PIO de 9mmHg sin medicamentos. Hasta donde sabemos, este es el primer Preserflo implantado en la cámara posterior descrito en la literatura (AU)


Assuntos
Humanos , Feminino , Idoso , Glaucoma de Ângulo Aberto/cirurgia , Endotélio Corneano , Lentes Intraoculares , Resultado do Tratamento , Pressão Intraocular , Campos Visuais
18.
J Fr Ophtalmol ; 44(8): 1229-1236, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34243998

RESUMO

PURPOSE: To examine the reproducibility of spectral domain optical coherence tomography (SD-OCT) segmented ganglion cell complex and circumpapillary retinal nerve fiber layer (cpRNFL) measurements in children with primary congenital glaucoma (PCG) in comparison with healthy children. METHODS: 12 children with PCG (G1) and 24 healthy children (G2) were recruited. The following SD-OCT measurements (Spectralis, Heidelberg Engineering) were made in one eye per child: total macular thickness (MT), thicknesses in several subfields and volumes of the three inner macular layers, macular retinal nerve fiber layer (mRNFL), ganglion cell layer (GCL), and inner plexiform layer (IPL) and cpRNFL thickness. In a single day, an expert operator obtained 3 circumpapillary and 3 macular measurements in each participant to determine intraoperator variability. Intraoperator repeatability was defined by the coefficient of variation (CoV) and intraclass correlation (ICC). RESULTS: ICC was excellent in both groups for cpRNFL measurements (G1 ICC=0.950 and G2 ICC=0.995) and for MT was excellent in G1 (ICC=0.957) and moderate in G2 (ICC=552). For the inner macular layer measurements, all ICCs were better in PCG group (mRNFL-ICC: 0.915 vs. 0.765; ICC-GCL: 0.584 vs. 0.263 and ICC-IPL: 0.979 vs. 0.742; G1 and G2 respectively). Greater CoV were recorded for macular measurements (from 0.71% to 9.82%) compared to cpRNFL measurements (from 0.52% to 1.50%). CONCLUSION: In children with PCG, Spectralis SD-OCT showed excellent intrasession repeatability for cpRNFL, MT, mRNFL and IPL measurements and moderated for GCL measurements. For all macular measurements, ICC were higher in children with PCG than healthy children.


Assuntos
Glaucoma , Macula Lutea , Criança , Estudos Transversais , Glaucoma/diagnóstico , Humanos , Pressão Intraocular , Reprodutibilidade dos Testes , Células Ganglionares da Retina , Tomografia de Coerência Óptica
20.
Arch Soc Esp Oftalmol (Engl Ed) ; 96(6): 299-315, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34092284

RESUMO

Our visual system has evolved to provide us with an image of the scene that surrounds us, informing us of its texture, colour, movement, and depth with an enormous spatial and temporal resolution, and for this purpose, the image formation (IF) dedicates the vast majority of our retinal ganglion cell (RGC) population and much of our cerebral cortex. On the other hand, a minuscule proportion of RGCs, in addition to receiving information from classic cone and rod photoreceptors, express melanopsin and are intrinsically photosensitive (ipRGC). These ipRGC are dedicated to non-image-forming (NIF) visual functions, of which we are unaware, but which are essential for aspects related to our daily physiology, such as the timing of our circadian rhythms and our pupillary light reflex, among many others. Before the discovery of ipRGCs, it was thought that the IF and NIF functions were distinct compartments regulated by different RGCs, but this concept has evolved in recent years with the discovery of new types of ipRGCs that innervate subcortical IF regions, and therefore have IF visual functions. Six different types of ipRGCs are currently known. These are termed M1-M6, and differ in their morphological, functional, molecular properties, central projections, and visual behaviour responsibilities. A review is presented on the melanopsin visual system, the most active field of research in vision, for which knowledge has grown exponentially during the last two decades, when RGCs giving rise to this pathway were first discovered.


Assuntos
Células Fotorreceptoras Retinianas Cones , Células Ganglionares da Retina , Ritmo Circadiano , Células Fotorreceptoras Retinianas Bastonetes , Visão Ocular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...